Journal of Biomechanics

Equipment used: 2 AMTI Force Plates - http://amti.biz/fps-guide.aspx

Philippe C. Dixon, Harald Böhm, Leonhard Döderlein, Ankle and midfoot kinetics during normal gait: A multi-segment approach, Journal of Biomechanics, Volume 45, Issue 6, 5 April 2012, Pages 1011-1016

http://dx.doi.org/10.1016/j.jbiomech.2012.01.001

Keywords: Oxford foot model; Multi-segment foot; Kinetics; Inverse dynamics; Gait analysis

Equipment used: 2 AMTI OR6-7-1000 Force Plates - www.amti.biz/OR6-7.aspx

Amir Haim, Guy Rubin, Nimrod Rozen, Yulya Goryachev, Alon Wolf, Reduction in knee adduction moment via non-invasive biomechanical training: A longitudinal gait analysis study, Journal of Biomechanics, Volume 45, Issue 1, 3 January 2012, Pages 41-45

http://dx.doi.org/10.1016/j.jbiomech.2011.10.017

Keywords: AposTherapy; Footwear-generated biomechanical training; Gait analysis; Knee adduction moment; Knee osteoarthritis; Plasticity of gait patterns

 

Equipment used: 2 AMTI Force Plates - http://amti.biz/fps-guide.aspx

Seyoung Kim, Sukyung Park, The oscillatory behavior of the CoM facilitates mechanical energy balance between push-off and heel strike, Journal of Biomechanics, Volume 45, Issue 2, 10 January 2012, Pages 326-333

http://dx.doi.org/10.1016/j.jbiomech.2011.10.009

Keywords: Step-to-step transition; Impulse; Mechanical work; Push-off; Heel strike

 

Equipment used: 1 AMTI Force Plate - http://amti.biz/fps-guide.aspx

Josien C. van den Noort, Martin van der Esch, Martijn P.M. Steultjens, Joost Dekker, H. Martin Schepers, Peter H. Veltink, Jaap Harlaar, The knee adduction moment measured with an instrumented force shoe in patients with knee osteoarthritis, Journal of Biomechanics, Volume 45, Issue 2, 10 January 2012, Pages 281-288

http://dx.doi.org/10.1016/j.jbiomech.2011.10.027

Keywords: Osteoarthritis; Gait; Joint moment; Biomechanics; Knee; Rehabilitation; Measurement system; Shoe

Equipment used: 1 AMTI Force Plate - http://amti.biz/fps-guide.aspx

Eirik Kristianslund, Tron Krosshaug, Antonie J. van den Bogert, Effect of low pass filtering on joint moments from inverse dynamics: Implications for injury prevention, Journal of Biomechanics, Volume 45, Issue 4, 23 February 2012, Pages 666-671

http://dx.doi.org/10.1016/j.jbiomech.2011.12.011

Keywords: Signal filtering; Joint moments; Anterior cruciate ligament

Equipment used: 1 AMTI MC3A-6-1000 Force Sensor – www.amti.biz/MC3.aspx

B. Carmichael, T. Dutta, G. Fernie, Forceshoes: Portable ground reaction sensors for biomechanical analysis in the work place, Journal of Biomechanics, Volume 39, Supplement 1, 2006, Page S537

http://www.sciencedirect.com/science/article/pii/S0021929006852097

Keywords: n/a

Equipment used: 1 AMTI Force Plate – http://amti.biz/fps-guide.aspx

Ugo Della Croce, Paolo Bonato, A novel design for an instrumented stairway, Journal of Biomechanics, Volume 40, Issue 3, 2007, Pages 702-704

http://dx.doi.org/10.1016/j.jbiomech.2006.01.020

Keywords: Dynamometry; Force platform; Human movement; Inverse dynamics

 

 

Equipment used: 1 AMTI AccuSway Force Plate – www.amti.biz/Accusway.aspx

Diana Glaser, Richard D. Komistek, Harold E. Cates, Mohamed R. Mahfouz, A non-invasive acoustic and vibration analysis technique for evaluation of hip joint conditions, Journal of Biomechanics, Volume 43, Issue 3, 10 February 2010, Pages 426-432

http://dx.doi.org/10.1016/j.jbiomech.2009.10.005

Keywords: Hip; Sound; Acoustic; Acceleration; In vivo

Equipment used: 2 AMTI Force Plates – http://amti.biz/fps-guide.aspx

G. Lenaerts, W. Bartels, F. Gelaude, M. Mulier, A. Spaepen, G. Van der Perre, I. Jonkers, Subject-specific hip geometry and hip joint centre location affects calculated contact forces at the hip during gait, Journal of Biomechanics, Volume 42, Issue 9, 19 June 2009, Pages 1246-1251

http://dx.doi.org/10.1016/j.jbiomech.2009.03.037

Keywords: Hip joint contact force; Hip geometry; Hip joint centre; Musculoskeletal model; Gait

 

Equipment used: 1 AMTI Force Plate – http://amti.biz/fps-guide.aspx

Carolin Curtze, At L. Hof, Helco G. van Keeken, Jan P.K. Halbertsma, Klaas Postema, Bert Otten, Comparative roll-over analysis of prosthetic feet, Journal of Biomechanics, Volume 42, Issue 11, 7 August 2009, Pages 1746-1753

http://dx.doi.org/10.1016/j.jbiomech.2009.04.009

Keywords: Prosthesis; Foot; Material testing; Inverted pendulum model; Curvature